Find the minimum number of receptacles a dwelling wall or kitchen countertop needs under NEC 210.52. Enter the run length and the tool applies the 6 ft / 12 ft wall rule (210.52(A)) or the 24 in / 4 ft countertop rule (210.52(C)(1)).

Wall or countertop run
Separate multiple runs with commas, e.g. 12, 8, 14

How to use this calculator

  1. Pick the location: a general living-area wall (210.52(A)) or a kitchen wall countertop (210.52(C)(1)). The spacing rule and thresholds change with it.
  2. Enter the length of the run in feet. For a whole room or a kitchen with several counter runs, enter each length separated by commas.
  3. Measure each wall space between openings; space that continues around a corner is one run, so enter it as a single length rather than splitting it at the corner.
  4. Read the minimum receptacle count, then the spacing rule: the maximum distance between receptacles and how close the first one must be to each end.
  5. Add the fixed specific-outlet requirements (bathroom, outdoor, laundry, basement, garage) separately: they are placed by location, not by spacing, and are noted below the result.

NEC reference

This calculator implements NEC 2020 210.52(A) and 210.52(C)(1). Under 210.52(A)(1) no point along the floor line of any wall space may be more than 6 ft from a receptacle, which sets a 12 ft maximum spacing and puts the first receptacle within 6 ft of each opening; 210.52(A)(2) defines a wall space as any run 2 ft or wider. Under 210.52(C)(1) a receptacle is required at each wall countertop or work surface 12 in or wider, placed so no point is more than 24 in from a receptacle, which sets a 4 ft maximum spacing. The result is the minimum count for which a compliant layout exists, rounded up.

Results are for reference only. Verify against the applicable adopted edition of the NEC and consult a licensed electrician for code compliance.

The spacing rule and the count formula

Both rules work the same way: a receptacle covers a fixed reach in each direction along the run, so the maximum spacing between two receptacles is twice that reach. The minimum count for a run of length L is L divided by the maximum spacing, rounded up, because a fractional receptacle is another whole receptacle.

Rule Reach Max spacing Counted at Count
210.52(A) wall 6 ft 12 ft 2 ft wide ceil(L / 12)
210.52(C)(1) countertop 2 ft (24 in) 4 ft 12 in wide ceil(L / 4)

Worked example: a 14 ft living-room wall

Take a 14 ft wall between two doorways. Dividing 14 by the 12 ft maximum spacing gives 1.17, which rounds up to 2 receptacles. In practice you would place one within 6 ft of the left doorway and one within 6 ft of the right, no more than 12 ft apart, so that every point on the wall is within 6 ft of a receptacle. A 12 ft wall would need only 1 (a single receptacle at the midpoint reaches both ends), and a 25 ft wall would need 3.

For a kitchen, a 10 ft run of counter divides by the 4 ft countertop maximum spacing to 2.5, rounding up to 3 receptacles, each no more than 24 in from any point on the counter and the first within 2 ft of each end.

Common mistakes

  • Measuring only the gap, not the ends. The 6 ft applies to the doorway and corner too, not just the space between receptacles, so the first receptacle cannot be more than 6 ft from where the wall space begins.
  • Splitting a corner run. Space measured around a corner is one continuous wall space under 210.52(A)(2). Splitting it at the corner can add a receptacle the code does not require.
  • Skipping short walls. Any wall space 2 ft or wider needs a receptacle. Only runs under 2 ft are exempt.
  • Confusing the counts. This is a placement rule for receptacles along a run. The number of branch circuits a dwelling needs is a separate calculation under 210.11.

Frequently asked questions

How far apart do receptacles have to be in a dwelling?

NEC 210.52(A) requires that no point along the floor line of any wall space be more than 6 ft from a receptacle. Because a receptacle reaches 6 ft each way, receptacles end up no more than 12 ft apart, with the first within 6 ft of every doorway or corner. This is the 6-foot, 12-foot rule.

What is the 6-foot, 12-foot rule?

The 6 ft is the maximum distance any point on the wall can be from a receptacle; the 12 ft is the resulting maximum spacing between two adjacent receptacles. A wall of length L needs at least L divided by 12, rounded up: a 12 ft wall needs 1, a 14 ft wall needs 2, and a 25 ft wall needs 3.

What counts as a wall space?

Under 210.52(A)(2) a wall space is any space 2 ft or more in width, unbroken along the floor line by doorways, fireplaces, and similar openings. Space around a corner is part of the same wall space. A run under 2 ft wide is not counted. Fixed room dividers and fixed wall panels are also treated as wall space.

How far apart are kitchen countertop receptacles?

NEC 210.52(C)(1) requires a receptacle at each wall countertop 12 in or wider, placed so no point is more than 24 in from a receptacle, a 4 ft maximum spacing with the first within 2 ft of each end. A 4 ft counter needs 1 and a 10 ft counter needs 3. Island and peninsula countertops follow their own rules and are out of scope here.

Does this give the total number of outlets in a room?

No. It gives the minimum general-purpose wall or kitchen countertop receptacles for the runs you enter. The fixed specific-outlet requirements, such as bathroom (210.52(D)), outdoor (210.52(E)), laundry (210.52(F)), and basement or garage (210.52(G)) receptacles, are additional and are placed by location, not by spacing.

Related calculators

Studying for the licensing exam? Our own NEC Code Quickstart works all twelve exam calculations start to finish, each with the code reference. Also in paperback. Going for the master license? NEC Master Electrician Exam Practice has 300 master-level questions with fully worked, table-cited answers, built on the 2023 NEC.

Running an electrical contracting business? Jobber handles scheduling, invoicing, and job management. Start a 14-day free trial.

Already have the software and the follow-up still is not happening? That is an unfilled seat rather than a missing tool. Our own Role Build covers the seat: three duties built to run start to finish inside the tools you already pay for.

For deeper NEC training on dwelling wiring and receptacle layout, Mike Holt's NEC courses are the industry standard.

Working from the printed code? NEC code books and tab sets are available from Mike Holt.

This page contains affiliate links. ElectricalToolbox may earn a commission when you sign up or buy through them, at no additional cost to you.

Get new tools and reference cards by email

Occasional emails when a new calculator, guide, or printable card ships. No spam, unsubscribe anytime.